Diesel generator startup time
Diesel generator startup time








  1. #DIESEL GENERATOR STARTUP TIME GENERATOR#
  2. #DIESEL GENERATOR STARTUP TIME MANUAL#

#DIESEL GENERATOR STARTUP TIME GENERATOR#

Solution: According to the actual ambient temperature, the corresponding low temperature measures should be adopted.Ī lack of diesel generator maintenance or operation knowledge will undoubtedly result in malfunction. Solution: Check whether the piston belongs to the model, if necessary, measure the combustion chamber volume. If the seal is not good, you should make a repair.ģ. Solution: Check the valve clearance, vlave spring, as well as the sealing of the valve guide and seat. Solution: Replace the piston ring, and replace the cylinder liner according to the wear condition. Excessive wear of piston ring and cylinder liner The compression pressure in the cylinder is insufficient fuel injection is normal but does not catch fire or fuel oil inside the exhaust pipeġ.

diesel generator startup time

Solution: Check whether the wiring is correct and reliable. Replace the new start-up battery if necessary.

diesel generator startup time

Solution: Use the battery with sufficient power, or increase the battery to use in parallel. The most common failure for diesel generator is battery failure. Solution: Check whether the oil inlet pipe is leaked or not and the filter screen on the oil inlet pipe connector is blocked or not. Oil Supply Problem – Oil transfer pump doesn’t supply oil or the oil supply is brokenly. Solution: Remove the fuel injector, connect it to the high pressure oil pump, pry the fuel injection pump plunger spring and observe the spray condition. Fuel Injector Problem – Little fuel injection or fuel injection is not atomized Solution: The handle position should be pushed to no-load when starting the diesel generator set. The Handle Position of Fuel Injection Pump Is Not Correct Solution: Clean the filter or replace the filter elementĤ. Solution: Check whether the pipeline is smooth or not.

#DIESEL GENERATOR STARTUP TIME MANUAL#

Loosen the bleed screw bolt on the diesel filter, and then use the manual oil pump to pump the fuel until the air bubble is gone. Solution: Check whether the fuel oil pipe connector is loose or not, and ensure that the air is cleared from the fuel system. This is a common problem that a diesel generator fails to start normally.

diesel generator startup time

If diesel generators fail to start, you can analyze the causes from fuel system failure, electric starting system failure, insufficient compression pressure in the cylinder and the low ambient temperature and other factors. After using a diesel generator for a long time, some malfunctions may occur that will cause the generator fail to start.










Diesel generator startup time